RC3000 Antenna Controller Appendix B-Mount Specific Data B-3
2.0 INSTALLATION
2.1.1 RC3000 Antenna Controller
The RC3000E is slightly deeper (19.1” vs. 17.05”) than the baseline RC3000. This additional depth is
required to accommodate the backpanel with MVO-style connectors.
2.1.4 Electronic Clinometer
The inclinometer should be rigged with the face vertical. With the face vertical, the inclinometer should
be mounted so that it is 19.0 (35.0 –16.0) degrees from vertical. This orientation will allow linear output
from the inclinometer to a RF angle of 90 degrees.
2.2 Electrical Connections.
The RC3000E’s backpanel contains the standard connectors for use with the RSI MVO’s antenna status
(J8) and motor control (J9) cabling. The following diagram shows this backpanel.
2.2.1 Power Entry
The RC3000E has the same fuse requirements as the RC3050A model (8 A. for 115, 4 A. for 230).
2.2.2 Motor Drive
2.2.3 Drive Sense
2.2.4 Limit Switches
2.2.7 Accessories
2.2.10 Pulse Sensors
Internal to the RC3000E is cabling that adapts these standard interface connections shown in the
baseline manual to the MVO style connectors on the backpanel. Schematics are provided in section 4.2
showing this adaptation.
NOTE: the RC3000’s Pulse Sensor inputs are used for sensing the status of the MVO’s feed type inputs.
The mechanization of these inputs is shown in the adapter cable schematic.
The individual MVO style connectors are now discussed.